
EKM6-630H 630A Advanced Circuit Breaker for High-Demand Industrial Applications
Why Quality Matters?
Grouped by product family for cleaner RFQ selection: one page shows the available variant SKUs and key specification choices without creating duplicate product pages.
Current Rating:
Rated Current:
Variant SKU:
RFQ inputs
Quantity, destination, certificate needs.
QC proof
Inspection and document review before shipping.
Export ready
Packaging and mixed-container planning.
Procurement Snapshot
Commercial details are confirmed by SKU, quantity and destination at RFQ stage.
RFQ checklist
Send these points with your inquiry for faster pricing.
Documents to confirm
Often sourced together
Technical Data
Specification values for buyer review and RFQ matching
| Product Family ID | OS-ETK-EKM6-630H |
|---|---|
| Variant SKU Count | 3 |
| Supplier | ETK |
| Supplier Model | EKM6-630H |
| Product Type | MCB / Circuit Breaker |
| Available Current Ratings | 400A / 500A / 630A |
| Available Voltage Ratings | 800V, 1000V, 1140V |
| Rated Voltage | 800V, 1000V, 1140V |
| Rated Current | 400A / 500A / 630A |
| Frame Current | 630A |
| Frame Size / Ways | 630A |
| Rated Current | 400,500,630A / 400A / 500A / 630A |
| Rated Voltage | 800V, 1000V, 1140V |
| System Voltage | 800V, 1000V, 1140V |
Product Overview
Three current variants from 400A to 630A for large inverter AC output protection and main distribution board feeders in utility-scale PV and C&I storage plants. At this current level the MCCB typically functions as a main incomer or bus section breaker requiring high breaking capacity and reliable trip performance.
At 400V AC three-phase, 630A represents approximately 435kW — appropriate for string inverter aggregation panels or medium central inverter output protection. At 690V AC, 630A handles approximately 753kW.
630A output MCCBs are used in centralised inverter configurations where multiple inverter modules share a common AC bus before the main transformer. The H-type frame designation confirms a higher breaking capacity suited to installation near transformer secondary busbars where grid fault currents are elevated.
Applications
Inverter output protection
AC distribution boards
EV and PV support circuits
Residential and commercial electrical BOS
Frequently Asked Questions
Is 630A sufficient for a 500kW central inverter?
At 690V AC three-phase, a 500kW inverter produces approximately 418A — within the 630A rating with margin. At 400V AC, 500kW produces approximately 722A — the 630A rated breaker would be undersized. Always check the inverter nameplate AC voltage and maximum output current.
Can EKM6-630H be used as a generator main switch?
AC MCCBs are commonly applied as generator main breakers. Confirm generator rated current, short-circuit contribution, whether motor-operated or shunt-trip variants are needed, and the generator grounding arrangement before specifying.
Technical Guides
Products & Systems
Markets & Services
Need project-specific engineering support?
Free CAD layout, wind/snow load calculations, and BOM review included with project orders.
Related Products
More components from the same application category.

EKM3-125DC Non-Polarity High-Current DC Miniature Circuit Breaker (Up to 125A)
EKM3-125DC Non-Polarity High-Current DC Miniature Circuit Breaker (Up to 125A) is organized as one O...

EKM6DC-800 High Capacity DC Circuit Breaker (630A-800A) - Enterprise Protection Solution
EKM6DC-800 High Capacity DC Circuit Breaker (630A-800A) - Enterprise Protection Solution is organize...

ETM1-63 Solar AC Circuit Breaker | 6kA Breaking Capacity
ETM1-63 Solar AC Circuit Breaker | 6kA Breaking Capacity is organized as one OmniSol product-family ...