12 in 1 out DC 1500V Combiner Box
Why Quality Matters?
Grouped by product family for cleaner RFQ selection: one page shows the available variant SKUs and key specification choices without creating duplicate product pages.
Variant SKU:
RFQ inputs
Quantity, destination, certificate needs.
QC proof
Inspection and document review before shipping.
Export ready
Packaging and mixed-container planning.
Procurement Snapshot
Commercial details are confirmed by SKU, quantity and destination at RFQ stage.
RFQ checklist
Send these points with your inquiry for faster pricing.
Documents to confirm
Often sourced together
Technical Data
Specification values for buyer review and RFQ matching
| Product Family ID | OS-ETK-EKDBT-PV12-1-BFS-1500 |
|---|---|
| Variant SKU Count | 1 |
| Supplier | ETK |
| Supplier Model | EKDBT-PV12-1-BFS-1500 |
| Product Type | PV Combiner Box |
| Available Voltage Ratings | 1500VDC |
| Rated Voltage | 1500VDC |
| Rated Current | 15A |
| Protection Degree | IP65 |
| DC Fuse | 1500VDC, 10×85mm, 15A; qty 24 |
| DC SPD | 1500VDC, 3P, 40kA, Type 2; qty 1 |
| Dimensions | 750x560x180mm |
| Enclosure | IP65, Metal (customizable shell materials) |
| Input Strings | 12 |
| Main Switch | 1500VDC, 250A 2P DC MCCB; qty 1 |
| Operating Temperature | -25°C to +55°C |
| Output Strings | 1 |
| Poles | 2P |
| Protection Degree | IP65 |
| Rated Current | 15A |
| Rated Voltage | 1500VDC |
| System Voltage | 1500VDC |
Product Overview
1500V DC version of the 12-string combiner for projects where string voltage exceeds 1000V. All internal fuse links, switching devices, and bus components must be rated for 1500V — replacing a 1000V combiner with a 1500V rated unit in a 1500V circuit is necessary for safety compliance.
At 1500V system voltage, string Voc can approach the full 1500V limit. Every component in the combiner box — fuse holders, fuse links, isolator, SPD, and busbar insulation — must carry 1500V DC rating.
The 1500V 12-string version extends combiner capability to 1500V DC system architectures. Verify that all internal components — bus bars, fuse holders, and monitoring connections — carry 1500V insulation ratings; do not substitute 1000V-rated internal components in a 1500V enclosure.
Applications
PV string combining
DC array protection
C&I rooftop solar
Utility-scale field combiner circuits
Frequently Asked Questions
Can I use a 1000V combiner box in a 1500V system if the string voltage is typically below 1000V?
No. Rating must be based on the maximum possible open-circuit voltage under coldest expected conditions, not the typical operating voltage. Module Voc at minimum temperature in a 12-string system may approach or exceed 1000V even if typical operating voltage is lower.
Are the fuse links inside 1500V-rated?
Yes — all internal gPV fuse links in a 1500V combiner must carry 1500V DC rating. Confirm that replacement fuse links are also 1500V rated (EKFL15D10L or equivalent) before servicing the combiner.
Technical Guides
Products & Systems
Markets & Services
Need project-specific engineering support?
Free CAD layout, wind/snow load calculations, and BOM review included with project orders.
Related Products
More components from the same application category.

1 in 1 out DC 1000V Combiner Box
1 in 1 out DC 1000V Combiner Box is organized as one OmniSol product-family page with 1 selectable v...

1 in 1 out DC 600V Combiner Box
1 in 1 out DC 600V Combiner Box is organized as one OmniSol product-family page with 1 selectable va...

12 in 1 out DC 1000V Combiner Box
12 in 1 out DC 1000V Combiner Box is organized as one OmniSol product-family page with 1 selectable ...